* Estimated delivery times start from the date of shipment, excluding processing time.
* Actual delivery times may vary due to holidays, weather conditions, or customs delays.
Libre nga standard shipping sa mga order nga sobra sa $9.9
Polisiya sa Pagbalik
Ang mga item nga ibalik dawaton sulod sa 40 ka adlaw gikan sa petsa sa pagdawat sa mga butang. Ang mga custom nga item dili mabalik o mabalhin. Ang mga item nga gipalit gamit ang e-gift card mabalhin lamang; ang refund dili magamit.
Libre nga Regalo
Welcome to Roymall, your professional website for purchasing premium department store gifts. We highly value and appreciate your support, and we want to express our gratitude by adding an extra touch of excitement to your purchases. When you shop with us, you not only get to enjoy high-quality products that enhance your lifestyle, but you'll also receive an exclusive free gift with every order you place. Ready to explore our collection and find your perfect gifts? Browse our selection of premium department store items, place your order, and look forward to the excitement of your free gift arriving alongside your purchase.
Polisiya sa Pagpadala
Among paningkamutan nga ihatud ang mga item kanimo human makuha ang imong mga order ug siguruon nga sila makaabot nga luwas. Ang mga detalye sa paghatud ipakita sa imong email sa pagkumpirma.Sa kadaghanan nga mga kaso, ang mga order giproseso sulod sa 2 ka adlaw.Sa espesyal nga mga kahimtang, kini madugay sama sa mosunod: Kung mag-order ka sa Sabado, Domingo o publiko nga mga holiday, kini madugay og 2 ka adlaw..Kasagaran, kinahanglan og 5-7 ka adlaw nga trabaho (Lunes hangtod Biyernes) nga wala maapektuhan sa paglangan sa flight o ubang mga hinungdan sa palibot..Tungod kay among serbisyo sa pagpadala kay sa tibuok kalibutan, ang mga oras sa paghatud magdepende sa imong lokasyon busa kini mahimong magkinahanglan og pipila ka panahon ug palihug hulata nga maligdong kung ikaw anaa sa layo nga mga distrito o mga nasud.
1. Polisiya sa Pagbalik & Pagbaylo
Among dawaton lamang ang mga item nga gipalit gikan sa roymall.com. Kung ikaw mopalit gikan sa among lokal nga mga tig-apod-apod o ubang mga tigbaligya, dili nimo kini mabalik sa among bahin.Ang mga item sa katapusang baligya o libre nga mga regalo dili madawat alang sa pagbalik.Aron kwalipikado alang sa pagbalik, ang imong item kinahanglan nga wala magamit ug sa parehas nga kahimtang nga imong nadawat. Kinahanglan usab kini anaa sa orihinal nga packaging.Human makuha ang mga instruksyon sa pagbalik gikan kanamo, palihug ipackage ang imong mga item nga ibalik ug ihulog ang imong package sa lokal nga post office o ubang courier. Among iproseso ang imong pagbalik o pagbaylo sulod sa 3-5 ka adlaw nga trabaho human namo kini madawat. Ang refund iproseso ug kredito awtomatik sa imong orihinal nga pamaagi sa pagbayad.Walay mga pagbalik o pagbaylo ang madawat kung ang produkto gipahiangay, lakip na ang custom size, custom
kolor, o custom printed.Kinahanglan og dugang nga tabang, palihug kontaka kami. service@roymall.com or Whatsapp: +8619359849471
2.Polisiya sa Refund
Makuha nimo ang bug-os nga refund o 100% store credit human namo madawat ang gibalik nga package ug susihon kini. Ang refund iproseso ug kredito awtomatik sa imong orihinal nga pamaagi sa pagbayad.Palihug hinumdomi nga ang mga gasto sa pagpadala ug bisan unsang mga buhis o bayad dili mabalik. Ang dugang nga mga gasto sa pagpadala dili mabalik kung ang package naipadala na. Ikaw ang responsable sa pagbayad niini nga mga bayad ug dili namo kini mabalik, bisan kung ang order ibalik kanamo.Human namo madawat ug makumpirma ang imong gibalik nga item, ipadala namo kanimo ang email aron pahibal-on nga among nadawat ang imong gibalik nga item. Pahibal-on usab namo kanimo ang pag-aprobar o pagsalikway sa imong refund.Kung aduna kay mga problema bahin sa proseso sa refund, palihug kontaka kami. service@roymall.com or Whatsapp: +8619359849471
20A DC Digital Multifunction Power Meter Energy Monitor Module Voltmeter Ammeter 6.5V-100V
Description:
Working Voltage
DC 6.5V-100V
Measuring Voltage
DC 6.5V-100V
Measuring Voltage
0-20A
Rated Power
2000W
Display
LCD
Display Format
Power
0.0-999.9W (<1KW)
1000-2000w(>1KW)
Energy
0-999Wh(<10KWh)
10-9999KWh(>10KWh)
Voltage
6.50-99.99V
Current
0.00-20.00A
Feature: - 20A DC multifunction power meter - LCD display wih backlight, easy to read - Bult-in shunt design, no extra needed - Power, current, voltage and energy display and monitor timely , easy to know electric energy consumption - Electric energy clear function, perfect for various device monitor separately
- Overload alarm function (over power alarm threshold, the backlight and voltage flashing alarm) - Power memory, shave the power parameter when power down, safe to use
Operaqtion Tips:
1. The backlight control
By short press the button to turn on or off the backlight, In the bakclight mode,the data will automatically store when power down
2. The energy cleared
Step 1: Press the power button 5 seconds until the digital display "CLr" , then release the button;
Step 2: Now it is in the "energy clear" mode, press the button again, the energy data is cleared and stop flashing;
Step 3: If in the "energy clear" mode you do not press the button in 5 seconds,then the energy data will not be cleared
3. Set power alarm value
Step 1: Press the button, when the power area display "SET ", release button,
Step 2:it is in the pweor alarming setting mode, the voltage area displays the highest value of the voltage alarm,the current area displays the lowest value of the voltage alarm. Then you can press the button quickly to increase the value" +1", when there is no key operation more than three seconds,
It happens that this power meter may give incorrect readings (more than should be). It can be calibrated by opening up the back and shorting the pads marked "W" on the PCB, then add 20V to the input and 1A load (20 Ohms) to the output. Then power on, wait for the display say "Pass" then power off and remove the short. Ta-daa: calibrated.
It happens that this power meter may give incorrect readings (more than should be). It can be calibrated by opening up the back and shorting the pads marked "W" on the PCB, then add 20V to the input and 1A load (20 Ohms) to the output. Then power on, wait for the display say "Pass" then power off and remove the short. Ta-daa: calibrated.
It happens that this power meter may give incorrect readings (more than should be). It can be calibrated by opening up the back and shorting the pads marked "W" on the PCB, then add 20V to the input and 1A load (20 Ohms) to the output. Then power on, wait for the display say "Pass" then power off and remove the short. Ta-daa: calibrated.
I did a whole bunch of looking around for a supply monitor for my power supply I am building. This one seemed great but the minimum 6.5V input meant I could not supply lower voltages. Upon reading the reviews I found one detailing that removing the diode "D" and placing the power monitor supply positive lead on the cathode (part of the diode with the line on it). allowed for lower voltages to be measured. So I tried it and it worked! Just tweaked the alarm trigger to 0V and now it works great!
I did a whole bunch of looking around for a supply monitor for my power supply I am building. This one seemed great but the minimum 6.5V input meant I could not supply lower voltages. Upon reading the reviews I found one detailing that removing the diode "D" and placing the power monitor supply positive lead on the cathode (part of the diode with the line on it). allowed for lower voltages to be measured. So I tried it and it worked! Just tweaked the alarm trigger to 0V and now it works great!
I did a whole bunch of looking around for a supply monitor for my power supply I am building. This one seemed great but the minimum 6.5V input meant I could not supply lower voltages. Upon reading the reviews I found one detailing that removing the diode "D" and placing the power monitor supply positive lead on the cathode (part of the diode with the line on it). allowed for lower voltages to be measured. So I tried it and it worked! Just tweaked the alarm trigger to 0V and now it works great!
Tips:For questions about your order, place of delivery, product discount, taxation, delivery time, warranty, shipping, payment, exchange rate, and other questions unrelated to the product, please contact customer service.
you too??
ordered mine March 10...still nothing as of April 19th.
you too??
ordered mine March 10...still nothing as of April 19th.
Answered by jsdavis55 on 20/04/2019Helpful (0)
0
Q:
Hello, The load part of the device was short-circuited and the shunt resistance between the negative connections inside was burnt. Does any one know the value of this resistance?
Regards //Turkish
Hey, hey,
The load part of the device was short-circuited and the shunt resistance between the internal negative connections burned. Does anyone know the value of this resistance?
Regards
Hello, The load part of the device was short-circuited and the shunt resistance between the negative connections inside was burned. Does anyone know the value of this resistance?
Regards //Türkish
Selam,
Cihazın yük kısmı kısa devre oldu ve içteki negatif bağlantılar arasındaki şönt direnç yandı. Bu direncin değerini bilen var mı?
Saygılar
hellocan you be more specific are you able to provide the R number or part number you are looking to replace, if that is not possible take a photograph of the damaged area and send it to me and I will see what I can do.as follow up if the parts you are refering to are R3
hellocan you be more specific are you able to provide the R number or part number you are looking to replace, if that is not possible take a photograph of the damaged area and send it to me and I will see what I can do.as follow up if the parts you are refering to are R3
Answered by clazh on 24/04/2020Helpful (0)
0
Q:
I bought this , received but want to seek help in connecting it.
I want to monitor a solar panel banks of 48VDC, do i need to get another 12V, input for the meter or what do i need to do to enable me use this meter to monitor the solar panels output volatge of 48VDC
I bought this , received but want to seek help in connecting it.
I want to monitor a solar panel banks of 48VDC, do i need to get another 12V, input for the meter or what do i need to do to enable me use this meter to monitor the solar panels output volatge of 48VDC
can i measure solar power with this i have 1 kva solar panels installed and connected to inverter
so i want to use this meter to connect inbetween solar and inverter to maesure current and voltage?
how
can i measure solar power with this i have 1 kva solar panels installed and connected to inverter
so i want to use this meter to connect inbetween solar and inverter to maesure current and voltage?
how
Hi Vaibhavkumar Birajdar, yes you could use this power meter. But be aware that you stay within it's parameters!...
Hi Vaibhavkumar Birajdar, yes you could use this power meter. But be aware that you stay within it's parameters!...
Answered by armin on 21/11/2019Helpful (0)
0
Q:
In case someone don't know, this instrument can be calibrated for precise measurements. For this, you need a power supply set to 20V and a 20 Ohm resistor connected to the Load terminals. Use thick and short cabling. Remove the back cover, and find the two empty jumper holes in the corner opposite to the connector terminals marked "W". Temporarily short this, then connect the power supply. The display says "CAL" then "PASS", release the power. The instrument is now calibrated. Make a test measurement, correct the voltage if necessary (if after calibration meter shows more than should, raise calibration voltage, calibrate again)
In case someone don't know, this instrument can be calibrated for precise measurements. For this, you need a power supply set to 20V and a 20 Ohm resistor connected to the Load terminals. Use thick and short cabling. Remove the back cover, and find the two empty jumper holes in the corner opposite to the connector terminals marked "W". Temporarily short this, then connect the power supply. The display says "CAL" then "PASS", release the power. The instrument is now calibrated. Make a test measurement, correct the voltage if necessary (if after calibration meter shows more than should, raise calibration voltage, calibrate again)
Common positive, the current measuring shunt is between the negative lines.
Common positive, the current measuring shunt is between the negative lines.
Answered by Aurum on 02/06/2019Helpful (0)
0
Q:
Hello banggod I have bught this meter but i have no idea how to use I want to measure the amount of power from the car headlight bulb How to right way to connect the wire to make it run correct
Hello banggod I have bught this meter but i have no idea how to use I want to measure the amount of power from the car headlight bulb How to right way to connect the wire to make it run correct
This meter only measures up to 100V DC. You could theoretically use a voltage divider circuit to give only 1/3 of your voltage to the meter. It would only show a value up to 100V but you just need to multiply it by 3 to get your total voltage.
This meter only measures up to 100V DC. You could theoretically use a voltage divider circuit to give only 1/3 of your voltage to the meter. It would only show a value up to 100V but you just need to multiply it by 3 to get your total voltage.
Answered by Fluvance on 04/11/2018Helpful (0)
Ask a Question
1.You can contact the customer service. for any question regarding the product.
2.Ask the question in English to get answer faster.